Fitmore hip replacement
Web开馆时间:周一至周日7:00-22:30 周五 7:00-12:00; 我的图书馆 WebNancy Crotti. FDA recently announced a Class I designation for a Zimmer hip replacement parts recall.. Certain Zimmer M/L taper with Kinectiv technology femoral stems and necks have "unexpected amounts of …
Fitmore hip replacement
Did you know?
WebEcho Bi-Metric Microplasty Stem. Part of Zimmer Biomet’s Echo Hip System, this stem is designed for minimally invasive surgical procedures. The stem of the Echo Bi-Metric … WebShort stems have the potential of being more bone conserving by allowing for higher neck retention, maintenance of the medial greater trochanter, and preferential stress transfer to the proximal femur. An initial experience with 500 new short stems (Fitmore, Zimmer Orthopedics) stems used for total hip arthroplasty is reported.
WebThe Taperloc Complete Hip System is compatible with ONE Planner Hip, a web-based preoperative planner for primary total hip arthroplasty. Using the auto-plan mode, surgeons can create a preoperative plan within five minutes.
WebOct 4, 2024 · Beyond 2–3 months. After 2–3 months of partial or total hip replacement, a person may be able to resume daily activities but should continue with daily physical therapy and regular walking. As ... WebFitmore® hip stem is a titanium alloy stem (Ti Al6V4) that has a porolock Ti-VPS coating in the proximal part to enhance bone ingrowth and is available in four different neck angle options (127°, 129°, 137°, 140°) and 14 different sizes (size 1–14) for each offset option [14].
WebJun 30, 2024 · Fitmore® hip stem is a titanium alloy stem (Ti Al6V4) that has a porolock Ti-VPS coating in the proximal part to enhance bone ingrowth and is available in four different neck angle options (127°, 129°, 137°, 140°) . A cementless titanium press-fit cup with or without screws (Allofit®/-S, ZimmerBiomet, Warsaw, IN, USA) was used in all ...
WebApr 1, 2024 · The operation of the century: total hip replacement. Lancet, 370 (2007), p. 1508. View PDF View article View in Scopus Google Scholar [2] ... Prospective clinical and radiostereometric analysis of the Fitmore short-stem total hip arthroplasty. Arch Orthop Trauma Surg, 136 (2016), p. 277. CrossRef View in Scopus Google Scholar [8] ctc youth parkWebThe Fitmore Hip Stem's short length and curved design helps preserve the patient's natural bone in the greater trochanter, where it matters most. Zimmer Biomet has been at the … earth apothecary hand soapWebJan 1, 2016 · Implatation of cementless endoprosthesis with Fitmore Hip Stem in the treatment of secondary hip osteoarthritis , is a good choice in the treatment of young patients with good bone quality ... earthappleWebHip replacement, also called hip arthroplasty, is a surgical procedure to address hip pain. The surgery replaces parts of the hip joint with artificial implants. The hip joint consists of a ball (at the top of the femur, also … earth apothecary hollywoodWebMar 21, 2011 · Description. The Zimmer Fitmore stem system is a curved, short (44 to 60 mm in length), uncemented femoral stem with a trapezoidal cross section and triple taper … earth apocalypse rustWebApr 22, 2016 · The Fitmore hip stem is designed to have apposition at the calcar and the lateral endosteal surface just distal to the level of the lesser trochanter. We planned to create three points of fixation of the stem within the intramedullary canal in order to obtain neutral stem alignment. ct cystogram icd pcs codeWebBackground: One million Total Hip Replacements (THA) are thought to be performed annually. To measure prosthesis awareness throughout daily activities, the FJS-12 patient-reported outcome scale was developed. This article’s goal is to undertake a psychometric validation of the Italian FJS-12 among a sample of related THA patients. … earth appeal